FMC DEL 1ns 4cha issueshttps://ohwr.org/project/fmc-delay-1ns-8cha/issues2019-02-12T09:07:41Zhttps://ohwr.org/project/fmc-delay-1ns-8cha/issues/1EEPROM type not compatible with VITA 57.12019-02-12T09:07:41ZDimitris LampridisEEPROM type not compatible with VITA 57.1In order to comply with VITA 57.1 standard, the FMC EEPROM needs to be
changed to 24C02.Federico VagaFederico Vagahttps://ohwr.org/project/fmc-delay-1ns-8cha/issues/11WR - "jumpless" switchover2022-12-12T09:19:48ZTomasz WlostowskiWR - "jumpless" switchoverEnabling the WR mode after a WR link failure causes a "jump" in the
card's time base, as the WR synchronization is re-done from scratch.
If the local time has not diverged too much (too much = a programmable
threshold), realign local time to WR with SoftPLL phase shifter only,
without touching PPS generator counters. This also applies to other
WR-enabled cards (TDC, ADC).Tomasz WlostowskiTomasz Wlostowski