1-wire thermometer chip Vih 0.1V too high.
Regarding the 1-Wire serial number / thermometer chip, the Maxim
DS18B20U+:
The data sheet says that when operated from a 3.3V supply (2.5V is not
possible), the minimum input high voltage level (Vih) is 2.2V.
On the other hand the Spartan 6 (that is used on the SPEC) data sheet
says that its minimum output high voltage level (Voh) on a 2.5V powered
bank is 2.1V. So it's close but not ideal.
- Verify above statement
- Decide if is acceptable or not.