Skip to content
Projects
Groups
Snippets
Help
Loading...
Sign in
Toggle navigation
P
Production Test Suite
Project
Project
Details
Activity
Cycle Analytics
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Charts
Issues
9
Issues
9
List
Board
Labels
Milestones
Merge Requests
0
Merge Requests
0
Wiki
Wiki
image/svg+xml
Discourse
Discourse
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Charts
Create a new issue
Commits
Issue Boards
Open sidebar
Projects
Production Test Suite
Commits
ea94680e
Commit
ea94680e
authored
Aug 01, 2013
by
Evangelia Gousiou
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
TDC calibration documentation added
parent
a9485953
Hide whitespace changes
Inline
Side-by-side
Showing
3 changed files
with
4 additions
and
4 deletions
+4
-4
TDC_PTScalibration_UserGuide.docx
...libration/documentation/TDC_PTScalibration_UserGuide.docx
+0
-0
TDC_PTScalibration_UserGuide.pdf
...alibration/documentation/TDC_PTScalibration_UserGuide.pdf
+0
-0
DAC_calibration.py
test/fmctdc1ns5cha/calibration/python/DAC_calibration.py
+4
-4
No files found.
test/fmctdc1ns5cha/calibration/documentation/TDC_PTScalibration_UserGuide.docx
0 → 100644
View file @
ea94680e
File added
test/fmctdc1ns5cha/calibration/documentation/TDC_PTScalibration_UserGuide.pdf
0 → 100644
View file @
ea94680e
File added
test/fmctdc1ns5cha/calibration/python/DAC_calibration.py
View file @
ea94680e
...
...
@@ -13,12 +13,12 @@
## |
##-------------------------------------------------------------------------------------------------
## |
## Description Calibration of the TDC DAC IC2 that control
ls the VCXO OSC2 which in turn
|
## Description Calibration of the TDC DAC IC2 that control
s the VCXO OSC2 which in turn
|
## controls the main timekeeping unit of the TDC application, the PLL IC4. |
## The test is using the pendulum CNT-91 as pulse generator sending pulses with a |
## period of
9
ms. The higher the DAC value, the higher the TDC is measuring the |
## the pulse period; for example with the DAC at 1.25V the TDC measures the
9
ms |
## period as 4,999967682 ms, whereas with the DAC at 1.65V the TDC measures the
9
ms |
## period of
5
ms. The higher the DAC value, the higher the TDC is measuring the |
## the pulse period; for example with the DAC at 1.25V the TDC measures the
5
ms |
## period as 4,999967682 ms, whereas with the DAC at 1.65V the TDC measures the
5
ms |
## period as 5,000000309 ms. |
## In this test:
## 1) we start with a bisectomy algorithm to find a first DAC value that brings the |
...
...
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment