Skip to content
Projects
Groups
Snippets
Help
Loading...
Sign in
Toggle navigation
A
ARRAY - LabVIEW Interface
Project
Project
Details
Activity
Cycle Analytics
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Charts
Issues
0
Issues
0
List
Board
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Charts
Wiki
Wiki
Snippets
Snippets
image/svg+xml
Discourse
Discourse
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Charts
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Projects
ARRAY
ARRAY - LabVIEW Interface
Commits
7c5dd01b
Commit
7c5dd01b
authored
Mar 06, 2019
by
Eva Sicking
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
Removed list of implemented features from README
parent
5f390114
Hide whitespace changes
Inline
Side-by-side
Showing
1 changed file
with
0 additions
and
140 deletions
+0
-140
README.md
README.md
+0
-140
No files found.
README.md
View file @
7c5dd01b
...
...
@@ -95,143 +95,3 @@ The following authors, in alphabetical order, have contributed to the project:
*
Manfred Valentan, HEPHY, @valentan
## List of implemented features
The following lists requested features that have been dealt with and either been rejected or implemented.
### REJECTED:
-
invert z scale when only negative values in HexPlot -> show values as they are recorded
-
overlay of all IV curves can be done offline and conveniently with
[
HexPlot
](
https://gitlab.cern.ch/CLICdp/HGCAL/HGCAL_sensor_analysis
)
-
temperature correction for IV -> should be done offline
### DONE commit 26.9.2017
-
add missing current indicator subtracting the sum of measured currents from the measured source current
### DONE commit 20.9.2017
-
slow down voltage ramp by a factor of 2
-
wait 15 seconds after measurement
### DONE commit 4.9.2017
-
implement interlock
-
skip higher voltages when compliance was reached once
### DONE commit 31.8.2017
-
restructure project structure, propagate changes to code
-
create shortcuts, introduce icon
-
reset abort button at start
### DONE commit 17.8.2017
-
reintroduce selection between sensor polarity but use just for contact test
-
reorder front panel
-
introduce debug features
### DONE commit 16.8.2017
-
remove polarity switch, data write out always as recorded
-
new HexPlot verison, convert geo files to new format
### DONE in between
-
verify HPK256 6 inch map with multimeter
-
update switchboard drivers from zip file in instr.lib
-
align columns with header
-
read only necessary voltage files
-
rename and restructure project
-
add separate IV and CV switch delays
### DONE commit 17.7.2017
-
voltage lists from file, if not user defined input
-
Fix last cell color
### DONE commit 12.7.2017
-
Polarity switch for contact test
-
fix open correction path
-
contact test now forward biased at 1V
-
fix bug open correction voltage selection dialogue
### DONE commit 11.7.2017
-
add guard ring to map files - between sensor and test capacitances => correct recorded data!
-
simplify init plots state
-
verify and activate SavePlots.vi in "Close" state
-
add possibility for sensor specific correction files
-
HexDAQ expected a file called /maps/Probe_card_HPK_6in_265chan.txt but there was only a file called ...265ch.txt
-
updated HexPlot.exe to fix numbering issue
-
add the guard ring to the list of channels to be scanned on channel 63.
### DONE commit 3.7.2017
-
add sufficient ":no" to match number of columns
-
insert plot on matrix command into output file
-
add 2nd column in map files to make them consistent with HexPlot maps
-
add maps read from files
-
fix sampling #1 std deviation bug
-
plot total current in uA
-
add HPK 8 inch 256 channels geo file
### DONE commit 29.6.2017
-
add HPK 8 inch geo file
-
negative voltages are integrated in a natural way. No extra button necessary.
-
added button to disable CV corrections
-
speed up by measuring total current and voltage only every X steps (set by user) and the first 10 steps to see if settled down
-
fix compliance behavior: when compliance, wait 5 seconds then check again. If still compliance, abort current voltage.
### DONE commit 27.6.2017
-
switch to PDF read mode programmatically
-
new HexPlot version which has -1000000 as default nan value
-
new geometry file for the switch matrix
-
add default value (-1000000) for open correction with missing correction data
### DONE commit 26.6.2017
-
test correct wiring with Take_Measurement.vi
-
fix stop button during ramp
-
test open correction functionality
### DONE commit 23.6.2017
-
warn and continue with next voltage when compliance is reached
-
fix stop button effect during ramp
### DONE commit 22.6.2017
-
refactored loop code
-
added OpenCorrection
### DONE commit 8.6.2017
-
fix actual voltage measurement from source
-
renamed main function to HexDAQ
-
added a field for analyzer's comments
-
improved front panel
### DONE commit 7.6.2017
-
added option for needle measurement
-
read values for open correction in (correction not yet applied)
### DONE commits April 2017
-
separate voltage delay for IV and CV
-
custom array for cells to measure
-
write out uncertainties
-
plot total current
### DONE commit 21.4.2017
-
new HexPlot.exe to cope with negative voltages when not specifying voltage
-
All parameters and HexPlot command written in datafile
-
Simplified VI's
-
corrected IV+CV voltage array bug
### DONE commit 7.4.2017
-
acquire probe card env sensor data
-
add 512 channel matrix test option: select sensor type "Full matrix"
-
separate file for single channel measurements
### DONE commit 6.4.2017
-
added optional pad numbers in HexPlot
-
save also all channels plot
-
automatically create folder per sensor identifier in specified storage location
-
IV + CV mode for automatic successive IV and CV scan
-
the main only works when started via the LabVIEW project
### DONE commit 4.4.2017
-
reinitialize single channel plot
-
added possibility for repetitive measurements
### DONE before
-
fixed switch matrix buffer readout that caused 0 temperatuture values while scanning
-
fixed single channel plot saving
-
fixed absurdely high values of source meter current
-
added adjustable LCR frequency and voltage settings
-
fix last line bug in text file