Skip to content
Projects
Groups
Snippets
Help
Loading...
Sign in
Toggle navigation
P
Production Test Suite
Project
Project
Details
Activity
Cycle Analytics
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Charts
Issues
9
Issues
9
List
Board
Labels
Milestones
Merge Requests
0
Merge Requests
0
Wiki
Wiki
image/svg+xml
Discourse
Discourse
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Charts
Create a new issue
Commits
Issue Boards
Open sidebar
Projects
Production Test Suite
Commits
19efb5a9
Commit
19efb5a9
authored
Jun 04, 2012
by
Matthieu Cattin
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
test24: Add a test to read calibration data from CP2103 EEPROM.
parent
32eadf27
Hide whitespace changes
Inline
Side-by-side
Showing
1 changed file
with
64 additions
and
0 deletions
+64
-0
test24.py
test/fmcadc100m14b4cha/python/test24.py
+64
-0
No files found.
test/fmcadc100m14b4cha/python/test24.py
0 → 100755
View file @
19efb5a9
#! /usr/bin/env python
# coding: utf8
# Copyright CERN, 2012
# Author: Matthieu Cattin <matthieu.cattin@cern.ch>
# Licence: GPL v2 or later.
# Website: http://www.ohwr.org
# Last modifications: 4/6/2012
# Import system modules
import
sys
import
time
import
os
import
re
# Add common modules and libraries location to path
sys
.
path
.
append
(
'../../../'
)
sys
.
path
.
append
(
'../../../gnurabbit/python/'
)
sys
.
path
.
append
(
'../../../common/'
)
# Import common modules
from
ptsexcept
import
*
import
rr
# Import specific modules
from
cp210x_eeprom
import
*
from
ctypes
import
*
import
find_usb_tty
"""
test24: Read calibration data from CP2103 EEPROM
The calibration box contains a voltage reference that has to
be calibrated for each input voltage range of the FmcAdc.
A multimeter of at least 6 digits has to be used for the
calibration. The result of the calibration is stored in the
cp2103 EEPROM.
"""
# Calibration box vendor and product IDs
BOX_USB_VENDOR_ID
=
0x10c4
# Cygnal Integrated Products, Inc.
BOX_USB_PRODUCT_ID
=
0xea60
# CP210x Composite Device
def
main
():
try
:
box_eeprom
=
CCP210x_Eeprom
(
"
%
X"
%
BOX_USB_VENDOR_ID
,
"
%
X"
%
BOX_USB_PRODUCT_ID
)
print
"Read calibration data from cp210x EEPROM."
calibr_data
=
box_eeprom
.
get_calibr_data
()
for
range_str
,
value
in
calibr_data
.
iteritems
():
print
"
%5
s range calibration voltage is:
%
s V"
%
(
range_str
,
value
)
except
(
CP210xEepromOperationError
)
as
e
:
raise
PtsError
(
"Test failed:
%
s"
%
e
)
if
__name__
==
'__main__'
:
main
()