Wesley W. Terpstra authored
Previously, the valid counter would increase on the last cycle of a strobe. Thus, if it were stalled forever, the counter would not increase. That posed a problem for software driven queues which need the counter to increase in order to receive an MSI to pop the queue via lowering stall.