Introduce adjustment parameter to timetag core and re-align all triggers.
Re-aligment was performed using the WR-enabled FMC-ADC and the PPS signal coming out from the WR switch as signal input on channel #1, as well as external trigger input. The PPS signal was delivered to the FMC-ADC by means of a 40ns coaxial cable. External, internal and time triggering well all tested and calibrated using the above setup.