    platform/xilinx: set g_phy_refclk_sel default value to 4. · 99932d24
    Dimitris Lampridis authored
    GTP reference clock is connected to CLK01 and/or CLK11 in our instance of GTP_DUAL.
    
    According to UG386, figure 2-3, page 41, REFSELDYPLLx must be set to '4' to select
    CLK10/CLK11.
    
    This is done in order to ensure backward compatibility with previous versions of
    the Xilinx platform support package.